Testbox for electronic coinvalidators and banknotereader
coin validators as there are: SECI
RM3/RM4/RM5, NRI G-13, Coin Controls C120/SR3 and many
more, as well as Banknotereader “Smiley” (ITL:
NV1,NV2,NV3, NV4). Strictly speaking the outlets of the above mentioned
devices will be controlled after coins
or notes have been accepted.
General characteristics: Supply
of the Testbox by the plug switch (GND outside/+ 12 V
inside) with the optionally obtainable plug socket-power
unit (Art.Nr.:9930400049) or with an equivalent socket
power unit. If the supply is correct, the green LED “POWER”
will light up. The socket-power unit should supply at least 800
mA, to provide the NV4-Banknotereader sufficiently
Usage hints: Validator:
SECI RM3/RM4/RM5,
NRI G13, Coin Controls C120, Cash Flow 330 and other pin
compatible types will be connected to the 10-pin plug jacket with a 10-pin
ribbon cable (Art.Nr. 9930500273) on the Testbox. The flashing of the
concerned LED 1 – 6 shows that the concerned outlet of the EMP is working
correctly. If one ore more red LED are lighting up permanently, the concerned outlets
are damaged (Short circuit!). If not any LED is flashing after accepting of a coin,
the coin outlet is damaged too.
Banknotevalidator:
“Smiley”should
be connected with a 15-pincable
(Art.Nr. 9930500168) to the 15-pin port of the Testbox.After
accepting a banknote the outlet s 1 –
4 will be tested, visible by flashing of the concerned LED 1 – 4.
If one or more red LED are lighting up permanently, the concerned
outlets are damaged (Short circuit!). If not any LED is
flashing after accepting of a banknote the outlet is damaged
too.
Options: With
the optionally obtainable programming stand (Art.Nr. 9930500417) the Coin Validator
can be tested comfortably and automatically in the correct position outside of the
host machine. For Testing the Coin Validator in mounted position
the flat ribbon cable with 2 additional couplings is suitable
best (Art.Nr. 9930500423). In this case the Coin Validator
and the Testbox will be directly supplied from the machine.
The Testbox is connected in parallel to the Coin Validator, with a 10-pin
ribbon cable upon one of the additional couplings. If it is given
not any or false credit, you can simply discern if the
error is caused by the Validator or by the host machine.
Hint:
The Testbox is safe from confusing polarity, that means: If the power supply
will be incorrectly installed, neither the Testbox nor the Test model will be destroyed
or damaged!
Technical specifications: Voltage: 12
VDC ±10% Power consumption: Stand by: 3 mA Max. 1,5 A Operating temperature:
0 - 55°C
Dimensions: Width: 56 mm High: 25 mm
Length: 80 mm Weight: 42 gr
Do you need further technical Informations?
Click here for ------> Manual
|